MembersPage/RobertNagy (2015-04-02 07:45:16)

VEMS Round with Motronic 7.1

VEMS Round using the following input:

- WBO2

- EGT

- Analog 1 --> 10 bar oil pressure sensor

- Analog 2 --> 400kPa VEMS Map sensor

Outputs:

- PWM0 -> reference RPM drive warning led for shiftlight

- PWM4 -> reference RPM drive "shift-now" led for shiftlight

Both PWMs should reference RPM and start sending PWM signal to the respective leds when reached the configured RPM.

Either needs a new target method for both PWM outputs or a hackish way is to configure an unreachable EGT or lambda target.

Sounds like a crap solution.

- Linear wideband output is connected to Motronic 7.1 for data-logging. (This Motronic ECU is dual-narrowband with dual EGTs for mixture preparation.)

- RPM input is coming from the Motronic RPM signal (instrument cluster), can this even be configured or do we need a crank signal?! If that's the case the documentation (Help) should be change to state something other than "RPM Signal".