I have a question about Wbo2 calibration
Is not possible calibrate the Wbo2 to 20,9 . When I change to ff = 255 Hex (wbo2_calibration=FF) the results become afr 20,1 and it not possible to go any higher.
Does anyone know what to be the problem??
- it's definitely pump_pid misconfiguration, the nernst cannot reach 4.45V (or more exaclty pump- + 0.45V)
- wbo2_pump_pid_ki=01 is surely wrong (where is the 01 value from?) try 0x20.. 0x40 or even 0x80 if you decrease wbo2_pump_pid_ilimit to appr 40..80)
- btw, measure RCal (resistance between sensor pin2 and pin6)
- Thanks Marcell
wbo2_pump_pid_ki=01 changes to 64 Hex all clear now
Best Regards
Peter