MembersPage/PerH/Problem1 (2026-05-05 02:21:41)

VR Sensor was dead.

Tested one i know works from another car in addition to the brand new one for this car, and the sensors were also verified to the EC36 connector using oscilloscope.

I also connected the VR sensor only i this test setup:

https://photos.app.goo.gl/bzDayVM8pNMGwoHA9

No luck, not one single trigger event in the log. Dead p259?

Reply from support:

Reply from Per:

Thanks, Will update with findings. I verified ground setup with a DVM earlier, but i'll check with a precision milliohm meter as well.

Measured the new VR sensor to 815ohms, and a older functional one to 650 ohms. Both make voltage when you put metal in front of it.

Update from Per:

Measured 0.4V on P259 VCC - Soldered off P259 VCC - Measured 5V on LM1815 VCC - Soldered P259 VCC back on - Trigger is working!

Maybe i found a short around the pin i took off?

Reply from support:

Update from Per: