History of MembersPage/PerH/Problem3
Older Newer
2026-05-05 02:31:46 . . . . 193.71.175.207 [new page]


Changes by last author:

Added:
I haven't tested much on this yet, but i was unable to get plug spark using test mode. Will look more at this and update.

Reply from support:

* always make sure to have GND return path. But with other problems, it is recommended NOT to try to spark. Use 1k resistor in series with a LED, and test output with that (the anode to +5V, testing 1 switched output at a time).

Reply from Per:

I found a passage about enabling the stepper driver in the user guide - setting water pump channel to S259/7 and start temperature to -40? (or using a misc output to activate S259/7 unconditionally). Maybe that was what was missing?

Update from Per:

That was it - setting up water pump channel did the trick, enabling the stepper driver unconditionally by activating S259/7 I now have sparks!