Injector Timing (Injector Angle tune)


The injector angle stop position is tunable from Firmware 1.1.80.

To disable this function just set all delay in the curve to 720.

To enjoy all advantage of this feature you need to have secondary trigger.

The injector angle curve shows the injecting end angle to TDC .

Injector actuation can be set from 210 to 720 degree before trigger tooth depends by Injector Angle curve.

If you want to disable this function use 720 degree everywhere.

This feature only avaliable to Primary injectors ( Staging injectors can not be delayed ).

The injector stop moments are tunable, but the minimum injector start moment is at trigger tooth.

So if you set bigger injector pulse width then delay, the injection starts at trigger tooth and stops when PW time elapsed ( like staging ).

Suggested value for new installs is between 210 and 370 degree.