Subpage of Base setup menu

Injector Staging Settings
To disable set TPS thershold to 100% and MAP threshold to 510kPa.
To enable this function there are some steps to follow:

Transition Fuel Trim
After activating staging you can trim +/- 2048us injector pulse width to both injectors

Rate to primary injectors
Same size = 100%, Smaller secondary stage = lower number, larger injectors = higher number, 630 primaries with 1680 secondary = 266%

Example:

number of Primary injectors = 4,
Rate to Primary Injector Size
= 100%,
injector 1 pulsewidth = 10ms when staging not active,

   after activating staging injector 0 pulsewidth will be 5ms

number of Primary injectors = 4,
Rate to Primary Injector Size
= 200%,
injector 1 pulsewidth = 10ms when staging not active,

   after activating staging injector 0 pulsewidth will be 3.33ms

Thresholds:
Secondary stage is activated when both TPS, MAP and RPM thresholds are exceeded.